Model 2000 Railroad Test Set

The Model 2000 is the perfect test set when no Cab Filters are needed. This economical unit has standard features which are not even available as options on competitive models such as:

Auto Polarity in DC functions
Selectable DC Amps Polarity
Direct measurement of Code Parameters
Ohmmeter Voltage Mode detects either polarity voltage including AC
Relay Contact On Time (Dry Contact) requires no adjustment

  • Base unit with no Cab Filters
  • Upgradable to a 2001, 2002 or 2003
  • Auto Polarity in DC functions
  • Selectable DC Amps Polarity
  • Direct measurement of Code Parameters
  • Relay Contact On Time (Dry Contact)
  • Requires no adjustment
  • Ohmmeter Voltage Mode detects either polarity voltage including AC
  • Field replaceable protective window

With Yellow Soft-Padded Carrying Case,
Cat No.
2010

The 2000 Series Railroad Test Sets

The 2000 Series Railroad Test Sets from Triplett Corporation are specialized VOM's designed for measuring the signal parameters of railroad coding equipment. They maintain compatibility with older technologies, while offering functions and features not found on standard VOM's.

Even for normal operation, the 2000 Series Railroad Test Sets are easier to use. Fewer jacks, more ranges, and a logical front panel layout all contribute to the 2000 Series' ease of use. The use of a multi-turn Ohms Adjust Control facilitates accurate resistance measurements. Also, the measurement of relay contact on time has been simplified and expanded requiring no adjustments.

Code Parameter measurements have been made simpler and more accurate. No longer is it necessary to count pointer swings to measure code rate. On Time can be measured on live signals as well as relay contacts. Peak Levels can be determined quickly and automatically. Adjustments to the code equipment peak level can also be made without constantly readjusting the Test Set. The 2000 Series Railroad Test Sets are also expandable. Optional circuit boards may be installed at any time to allow for the filtering of 60Hz, 100Hz, 200Hz, or 250Hz Cab Signals. The base unit Model 2000 may be upgraded at any time to include these filters without losing your initial investment.

The 2000 Series Railroad Test Sets from Triplett Corporation, once again, leaving the competition dead in its tracks!

Features

2000 SERIES ENHANCED FEATURES
Auto-polarity on all DC functions with red NEG indicator. Ohmmeter Voltage Mode detects foreign voltage of either polarity. Multi-turn Ohmmeter Adjust for more accurate setting of Ohmmeter zero. Power saving sleep feature prevents draining of the batteries if accidentally left on. Dry contact requires no adjustment to measure relay contact on time. Measures rate directly without counting pointer swings. Can detect and hold 2 msec momentary closures. Selectable DC Amps Polarity (Auto, Positive, Negative). Will measure pulse code transmit and receive currents independently.

DIRECT MEASUREMENT OF CODE PARAMETERS
Directly measures code parameters in any AC or DC range. No counting of pointer swings or adjustments are necessary. Peak Follow allows downward adjustment of peak levels.
 
Peak Level
Rate
On Time

Accurately measures code parameters to 420 cpm.

CAB FILTER OPTIONS (2001,2002, & 2003)
Allow measurements of all code parameters for selected cab frequencies without shutting down equipment. Active in all AC Volts and AC Amps Ranges.

SAFETY FEATURES
Shrouded safety jacks and spring-loaded shroud on test lead plugs. Fused on all ranges and functions except 6A and 30A. Battery/Lamp Test and Battery Monitor prevent false readings from weak batteries.

MECHANICAL FEATURES
Rugged, lightweight, weather-resistant case. Secondary protective window (field replaceable). Modular construction for easier repair and upgrade. One Year Warranty on construction and calibration.

Model 2000 Base Unit with no Cab Filters Upgradable to a 2001, 2002, or 2003 at any time.


Specifications


DC VOLTAGE RANGES: 0.6, 3, 15, 60, and 300 VDC.
ACCURACY: ± 1.5% of full scale.
SENSITIVITY: 1000 ohms per volt.
DC MILLIAMPS RANGES: 15, 60, and 300 mA DC.
ACCURACY: ± 1.5% of full scale.
BURDEN VOLTS: 60 mV nominal.
DC AMPS RANGES: 1.5, 6, and 30 Amps DC.
ACCURACY: ± 1.5% of full scale.
BURDEN VOLTS: 60 mV nominal.
AC VOLTAGE RANGES: 1.5, 3, 15, 150, 300, and 600 VAC
ACCURACY: ± 3.0% of full scale.
SENSITIVITY: 288 ohms per volt.
CALIBRATION: Average responding, RMS calibrated.
FREQUENCY RESPONSE: 25Hz to 400Hz.
AC AMPS RANGES: 1.5, 6, and 30 Amps AC.
ACCURACY: ± 3.0% of full scale.
BURDEN VOLTS: 60 mV nominal.
CALIBRATION: Average responding, RMS calibrated.
FREQUENCY RESPONSE: 25Hz to 400Hz.
CAB FILTER
RESPONSE
(all AC Ranges)
60Hz Filter: 57 to 64Hz (2003)
100Hz Filter: 92 to 100Hz
(2001, 2002, 2003)
200Hz Filter: 196 to 204Hz
(2002)
250Hz Filter: 245 to 255Hz
(2001)
All filters introduce an additional ± 1.5% level error.
CODE
FUNCTIONS
(all AC &
DC Ranges)
ON TIME:
RANGE: 3% to 100%
ACCURACY: ± 3.0% of full scale
RATE:
RANGE: 30 to 500 CPM
ACCURACY: ± 3.0% of scale length
PEAK HOLD:
Captures and holds highest level peak.
PEAK FOLLOW:
Displays all peaks > 25% of previous peaks.
OHMMETER VOLTAGE SENSE MODE
RANGE: 15 V AC or DC
ACCURACY: ± 20% Typical
SENSITIVITY: 1000 ohms per volt

RESISTANCE MEASUREMENT MODE
RANGES: R x 1 and R x 100
CENTER SCALE: 5 and 500 ohms
ACCURACY: ± 2% of scale length ± 0.5 ohms
OPEN CIRCUIT VOLTAGE: 1.0 to 1.8 VDC

DRY
CONTACT
ALLOWABLE CONTACT RESISTANCE: 0 to 100 ohms
TEST VOLTAGE: 7.5 to 15 VDC
TEST CURRENT: 830 A max.
ON TIME:
RANGE: 0 to 100%
ACCURACY: ± 2% of full scale
RATE:
RANGE: 30 to 500 cycles per minutes
ACCURACY: ± 3% of scale length
PEAK HOLD:
Pointer will deflect to full scale and remain there with a 2.0 millisecond or longer contact closure.
POWER
REQUIREMENTS
BATTERIES: Two, 9 volt alkaline (NEDA 1604) One, 1.5 volt alkaline D-cell (NEDA 13F)
BATTERY LIFE: 320 hours typical, 2000 hours in Sleep Mode
METER
MOVEMENT
ELECTRICAL: 100 A ± 1% at full scale
CONSTRUCTION: Taut band, shock mounted, 100 degree deflection, critically damped, Mirrored Scale, Bar-ring magnet.
PHYSICAL
SPECIFICATIONS
SIZE: 5.0" wide x 6.5" high x 3.2" deep
WEIGHT: Approx. 2.75 lbs., Approx. 4.75 lbs. w/case and leads.
OPERATING TEMPERATURE RANGE: -40° C to +85° C

Accessories & Replacement Parts


Catalog No. Description
37-24 1.5 Volt Battery, Eveready No. E95 (D-Cell)
37-38 9 Volt Battery, Mallory MN 1604
10-3967 Soft-Padded Carrying Case (Yellow Nylon) w/strap
79-729 Test Leads
84-710 Instruction Manual
3206-75 Shoulder Strap for Padded Case (Yellow)
3206-77 Hold down straps (for 2000 Series w/Padded Case, 2 required)
3207-21 Fuse, 10 AMP / 250 Volt 3AG
3207-30 Fuse, 1 AMP / 250 Volt 8AG
13568 Protective Window w/ screws

 