Features:
4000 M ohm/V Reading/10,000M ohm analog indication
Test Hold function easy to catch up the value
Backlighted illumination
3-3/4 Digital LCD, 4000 Count
Autorange for Mega Ohm range
50 segments Log Scaled Analog Display
Easy to carry testing package
Tests insulation at rated voltage into a 1mA load
200mA short circuit continuity current
Meets VDE 0413 |
VDE 0413 / IEC 1010
Display: 80 x 50mm Big LCD Panel with 50 segments analog display Max Reading 4000
Over range Indication: OL will be shown on the LCD Panel when out of
range measurement is made
Low Battery Indication: The B will be shown when the battery needs to be changed
Sampling Time: 2.5 times/sec Digital Display 10 times/sec Bar Graph
Power Source: Eight 1.5Volt AA Batteries
Operating Temperature and Humidity: 0°C to 40°C (32°F to 104°F), below 80% RH
Storage Temperature: -10°C to 60°C (14°F to 140°F)
Dimensions: 200(L) x 140(W) x 95(H)mm
Weight: Approx. 900g (with battery)
Accessories: Test Lead, Battery, Instruction Manual |
Electrical Specifications:
AC Voltage
Range: 600V ACV
Resolution: 0.1V
Accuracy: 1.5% rdg + 3 dgt (1V~600V)
Continuity
Range: 400? (Ish>200mA)
Resolution: 0.1?
Accuracy: 1% rdg + 5 dgt
Meg Ohm Range:
4000Mohm/250V w/autorange 4000M/400M/40M/4M
4000Mohm/500V w/autorange 4000M/400M/40M/4M
4000Mohm/1000V w/autorange 4000M/400M/40M/4M
Resolution: 4000Mohm50V, 1 Count/1Kohm
4000Mohm/500V, 1 Count/1Kohm
4000Mohm/1000V, 1 Count/1Kohm
Accuracy: 3% rdg + 5 Count (under 1G?
5% rdg + 3 Count (under 4G?)
|