Round Meter - Model 1235 (3½")

Polycarbonate Case & Window
Molded Matte Finish
Hi Temperature Polycarbonate
    Case
Bold lettering and scale arcs that
    provide clean , crisp readability
Self-shielding mechanism for
    mounting on either magnetic or non-
    magnetic panels
Wide selection of ranges
Options
Glass Window
¼" Terminal Spacing
Pivot & Jewel Mechanisms
Special Accuracy & Tracking 
     specifications
Customized Scales
Mirrored Scales
Special Ballistic Response
Temperature Compensation
Special Resistance
The versatile Model 1235 Round Panel meter has been designed for cost effectiveness while maintaining the quality that has made LFE/api
by Triplett a leader in the test and measurement market.  The Model 1235 is available in AC, DC, Pyrometer and Process Control Ranges.
Special Ranges and Options are available to meet your instrumentation requirements.

Round Meter Model 1235 Specifications

Specifications
(Taut Band)

DC Ranges AC Ranges (Rectifier Type) Pyrometer
Current Voltage Current Voltage
Accuracy

±2%

±2%

±3% ±3% ±2%
Tracking Optional Optional Optional Optional N/A
Balance ±1% ±1% ±1% ±1% ±1%
Repeatability

Taut Band Mechanism

< ¼% < ¼% < ¼% < ¼% < ¼%

Pivot & Jewel

2% 2% 2% 2% N/A
Resistance Tolerance ±20% ±5% ----- < 10V ±20%
> 10V   ±5%
N/A
Overload
Capacity
1 Second 1000% < 100V 1000%
> 100V   200%
150% 150% N/A
Continuous 150% 120% 150% 120% N/A
Calibration Frequency -------- -------- 60 Hz 60 Hz N/A
Overshoot (maximum) 20% 20% 20% 20% N/A
Response Time
(maximum)
Sensitivity>50µa 1.5 sec 1.5 sec 1.5 sec 1.5 sec N/A
Sensitivity<50µa 3 sec 3 sec 3 sec 3 sec N/A
Effects of shock, vibration,  humidity and temperaure are equal to or better than ANSI C39.1-1981
Safety(dielectric test , leakage and other hazards) instruments are equal to or better than ANSI C39.5-1974
The above tolerance limits apply to the standard ranges listed in this bulletin. Special instrumants may vary

from these limits.Rated circuit to ground voltage = 800 Vrms (1100 Peak).
Model 1235 Dimensions
Model Height Width Depth

1235 (3½")

3.53" 3.53" 1.9"
DC Ranges Process Ranges AC Ranges
DC Microamperes 5 to 1000 DC Millamperes 1-5, 4-20, 10-50 AC Microamperes 100 to 1000
DC Milliamperes 1 to 1000 DC Volts 1-5, 0-10 AC Milliamperes 1 to 1000
DC Amperes 1 to 50


For Thermocouple Pyrometers
or VU Meters Contact IMS

AC Amperes 1 to 50
DC Millivolts 5 to1000 AC Millivolts 250 & 500
DC Volts 1 to 500 AC Volts 1 to 500

Back to LFE/api Link Index

Triplett Panel Meters Index

Phones: 800-926-3837....818-841-2417.......FAX 818-841-2379

We accept: Visa - MasterCard -American Express

Jump to IMS (Instrument Meter Specialties) Home Page)

Copyright © 1998-2001 Instrument Meter Specialties