Distributed By: Instrument Meter Specialties |
Black Phenolic, Long Scale & Bezel Panel Meters |
Model 426 (4 ½") |
Models: 361 (3½") , 561 (5½") |
| The Model 426 is a versatile panel meter with a low-profile thin front. It has a scale approximately equivalent to that of a convential 4½ " meter, but the dial area height is the same as a 3½ " meter. The Model 426 requires no more panel space than other meters with shorter scales. Designed so that it is equally attractive and practical wether mounted in front of a panel or recessed. . The Model 426 has found immediate acceptance in today's narrow rack panels | The Models 361 & 561 have the meter bezels molded into their cases for thru the panel bezel mounting. Panel meter installation is quick and easy since there is no separate bezel hardware. |
Black Phenolic panel meters are rugged, stylish, sensistive and accurate. They
range in size from 3½" to 5½" and can be either front or bezel mounted.
Their rugged designs are particularly suitable for use in demanding environments.
The Black Phenolic Panel Meters have
a standard indication accuracy of ±2% full scale for DC ranges (±3% for AC ranges) and
are available with "Super Calibrated Accuracy"
of ±0.5% for exacting measurement requirements.
Black Phenolic, Long Scale & Bezel Panel Meters Specifications |
||||||
Specifications |
DC Ranges | AC Ranges (Rectifier Type) | Pyrometer | |||
| Current | Voltage | Current | Voltage | |||
| Accuracy | ±2% |
±2% |
±3% | ±3% | ±2% | |
| Tracking | Optional | Optional | Optional | Optional | N/A | |
| Balance | ±1% | ±1% | ±1% | ±1% | ±1% | |
| Repeatability | Taut Band Mechanism |
< ¼ % | < ¼ % | < ¼ % | < ¼ % | < ¼ % |
Pivot & Jewel |
2% | 2% | 2% | 2% | N/A | |
| Resistance Tolerance | ±20% | ±5% | ----- | < 10V ±20% > 10V ±5% |
N/A | |
| Overload Capacity |
1 Second | 1000% | < 100V 1000% > 100V 200% |
150% | 150% | N/A |
| Continuous | 150% | 120% | 150% | 150% | N/A | |
| Calibration Frequency | ---- | ---- | 60 Hz | 60 Hz | N/A | |
| Overshoot (maximum) | 20% | 20% | 20% | 20% | N/A | |
| Response Time (maximum) |
Sensitivity>50µa | 1.5 sec | 1.5 sec | 1.5 sec | 1.5 sec | N/A |
| Sensitivity<50µa | 3 sec | 3 sec | 3 sec | 3 sec | N/A | |
| Effects of shock, vibration, humidity and
temperaure are equal to or better than ANSI C39.1-1981 Safety(dielectric test , leakage and other hazards) instruments are equal to or better than ANSI C39.5-1974 The above tolerance limits apply to the standard ranges listed in this bulletin. Special instrumants may vary from these limits. Rated circuit to ground voltage = 800 Vrms (1100 Peak). |
||||||
| DC Ranges | Process Ranges | AC Ranges (Rectifier Type) | |||
| DC Microamperes | 5 to 1000** | DC Millamperes | 1-5, 4-20, 10-50 | AC Microamperes | 100 to 1000 |
| DC Milliamperes | 1 to 1000 | DC Volts | 1-5, 0-10 | AC Milliamperes | 1 to 1000 |
| DC Amperes | 1 to 50 | Contact IMS for: VU Meters &
Thermocouple Pyrometers |
AC Amperes | 1 to 50 | |
| DC Millivolts | 5 to1000 | AC Millivolts | 250 to 500 | ||
| DC Volts | 1 to 500 | AC Volts | 1 to 500 | ||
| Black Phenolic , Bezel Dimensions | ||||
| Model | Height(") | Width(") | Depth(")* | Phones: 800-926-3837....661-945-5664.......FAX 661-339-2309
|
| 361 (3½") | 2.005 | 3.54 | 2.14 | |
| 426 (4½") | 2.98 | 4.54 | 2.00 | |
| 561 (5½") | 2.70 | 5.05 | 3.00 | |
Jump to IMS (Instrument Meter Specialties) Home Page)
Copyright © 1998-2001 Instrument Meter Specialties