Distributed By: Instrument Meter Specialties |
Black Panelist - Clear Panelist - Stylist |
| Black Panelist ( Phenolic ) | Clear Panelist | Stylist |
| Models: 303(3½") 503(4½") | Models: 202(2½") 302(3½") | Models: 1202(2½") 1302(3½") |
| 603(5½") | 502(4½") 602(5½") | 1502(4½")1602(5½") |
|
|
|
| A rugged case and clear glass window make the Black Phenolic Panelist suitable for industrial environment | The Clear Panelist is popular for
front-mounting applications. It can also be mounted behind the panel with special hardware. |
A Clear Panelist can be converted to a Stylist by adding a bezel. A small stock of panelist/stylist can meet many product requirementst that would other- wise require a large inventory of instruments.The bezel atttaches the instrument to the panel withe two simple retaining clamps |
Black Panelist, Clear Panelist & Stylist Specifications |
||||||
Specifications |
DC Ranges | AC Ranges (Rectifier Type) | Pyrometer | |||
| Current | Voltage | Current | Voltage | |||
| Accuracy | ±2% |
±2% |
±3% | ±3% | ±2% | |
| Tracking | Optional | Optional | Optional | Optional | N/A | |
| Balance | ±1% | ±1% | ±1% | ±1% | ±1% | |
| Repeatability | Taut Band Mechanism |
< ¼ % | < ¼ % | < ¼ % | < ¼ % | < ¼ % |
Pivot & Jewel |
±2% | ±2% | ±2% | ±2% | N/A | |
| Resistance Tolerance | ±20% | ±5% | ----- | < 10V ±20% > 10V ±5% |
N/A | |
| Overload Capacity |
1 Second | 1000% | < 100V 1000% > 100V 200% |
150% | 150% | N/A |
| Continuous | 150% | 120% | 150% | 150% | N/A | |
| Calibration Frequency | ---- | ---- | 60 Hz | 60 Hz | N/A | |
| Overshoot (maximum) | 20% | 20% | 20% | 20% | N/A | |
| Response Time (maximum) |
Sensitivity>50µa | 1.5 sec | 1.5 sec | 1.5 sec | 1.5 sec | N/A |
| Sensitivity<50µa | 3 sec | 3 sec | 3 sec | 3 sec | N/A | |
| Effects of shock, vibration, humidity and
temperaure are equal to or better than ANSI C39.1-1981 Safety(dielectric test , leakage and other hazards) instruments are equal to or better than ANSI C39.5-1974 The above tolerance limits apply to the standard ranges listed in this bulletin. Special instrumants may vary from these limits. Rated circuit to ground voltage = 800 Vrms (1100 Peak). |
||||||
| Black Panelist (Phenolic) Dimensions | Clear Panelist Dimension |
Stylist Dimension |
|||||||||
| Model | Height | Width | Depth* | Model | Height | Width | Depth* | Model | Height | Width | Depth** |
| 303 (3½") | 3.12 | 3.27 | 1.80 | 202 (2½") | 2.31 | 2.25 | 1.82 | 1202(2½") | 1.47 | 2.59 | 2.55 |
| 503 (4½") | 4.27 | 4.71 | 1.86 | 302 (3½") | 3.02 | 3.16 | 1.85 | 1302(3½") | 2.02 | 3.53 | 2.55 |
| 603 (5½") | 4.36 | 5.75 | 1.86 | 502 (4½") | 4.15 | 4.60 | 1.85 | 1502(4½") | 2.94 | 5.04 | 2.55 |
| 602 (5½") | 4.25 | 5.62 | 1.85 | 1602(5½") | 3.39 | 6.14 | 2.55 | ||||
Dimensions are in inches
*Depth = front of panel to end of terminals
**Depth= 2.55" + Panel Thickness
| DC Ranges | Process Ranges | AC Ranges | |||
| DC Microamperes | 5 to 1000** | DC Millamperes | 1-5, 4-20, 10-50 | AC Microamperes | 100 to 1000 |
| DC Milliamperes | 1 to 1000 | DC Volts | 1-5, 0-10 | AC Milliamperes | 1 to 1000 |
| DC Amperes | 1 to 30 | Contact IMS for: VU Meters &
Thermocouple Pyrometers |
AC Amperes | 1 to 50 | |
| DC Millivolts | 5 to1000 | AC Millivolts | 250 to 500 | ||
| DC Volts | 1 to 500 | AC Volts | 1 to 500 | ||
Phones: 800-926-3837....661-945-5664.......FAX 661-339-2309
We accept: Visa - Mastercard -American
Express
Jump to IMS (Instrument Meter Specialties) Home
Page)
Copyright © 1998 Instrument Meter Specialties