3 ½½ DIGIT  USER ADJUSTABLE SPECIFICATIONS

INPUTS

Power Options (User Selectable Screw Terminal)
DC Voltage & Current:
Accuracy:   ± (0.1% + 1 Count )Typical
                   ± (0.2% + 1 Count  Maximum
Protection:  mVDC: 200V Continous, 350V Int.
                   VDC: 350V Continous, 500V Int.
                   DC Shunt: 5V Maximum
115 & 230VAC: 50 to 60 Hz & (110 & 220VDC)
-15%,+ 10%, <2VA at 115VAC, <3VA at 230VAC.
12 & 24VDC Isolated: -15%,+20%, 105maDC
                                     with Backlighting
10 to 15 DC & 16 to 32VDC Non-Isolated:
105 mADC with Backlighting
AC TRMS Voltage & Current
Accuracy:   ± (0.5% + 1 Count )Typ. Res 1 Meg
Protection:  AC: 350V Continous, 500V Int.
                   AC Current: Full Scale
                   2A & 5A; 120% Full Scale
SCALING (AC TRMS,Process,DC Isolated Inputs)
Full Scale SPAN Adjustment:
Coarse Adjustment: Four Ranges set by Dip Switch
           100 to 400 Counts        800 to 1500 Counts
           400 to 800 Counts       1500 to 2000 Counts
Fine Adjustment: 25 Turn Potentiometer
Zero OFFSET Adjustment:
Fine Adjustment with 25 Turn Potentiometer.
±  15% of Full Scale (for Process Input)
±  10% of Full Scale (for AC TRMS Input)
Frequency:
Accuracy:  40.0 to 199.9 Hz Range:
                       ± 0.2Hz. 40 to 70 Hz
                       ± 0.5Hz. 70 to 199.9 Hz
                  40 to 600 Hz Range:
                       ± 2Hz. 40 to 600 Hz
                  Less than 0.2 Hz error for up to 20%
                  Third Harmonic Distortion
Loop Powered Process (4 to 20mADC):
Protection: 30mA Forward, 75MADC Reverse
Burden:      2.2 Max with Reverse Current Protection
                   1.5V Options Contact IMS
Operating Temperature: -30° to +65°C
SCALING (Loop Power, DC Shunt & Non-Isolated
Full Scale SPAN Adjustment:
Coarse Adjustment: Four Ranges set by Dip Switch
           100 to 250 Counts        500 to 1000 Counts
           400 to 500 Counts       1000 to 2000 Counts
Fine Adjustment: 25 Turn Potentiometer

Zero OFFSET Adjustment (Loop Powered Only)
Three Choices set by Dip Switch:
           -20 to +20 of SPAN
            True Zero (4maDC=20% of SPAN).
Fine Adjustment: 25 Turn Potentiometer
Process (4 to 20mADC):
Protection: 100mADC
Burden:      240mVDC @ 20mADC
                ENVIRONMENT
Operating Range:       - 0 to +40°C Standard
                                  -20 to +60°C Optional
Storage Range:          -10 to +60°C Standard
                                  -30 to +70°C Optional

DISPLAY

BACKLIGHT OPTIONS

Digits:         3½ ( ±1999)
Type:          7 Segment LCD
Height:       0.5" (12.7mm)
Polarity:    Automatic, (-) Displayed
Overload: Three lower order digits blank
                  for >1999 counts
Decimal Point:  3 Position, Switch Selectable
Non-Backlit                 
Red Negative              
Green Positive
Green Negative

PERFORMANCE

Conversion Rate:              2.5 per Secont
Normal Mode Rejection:  >30db @ 60Hz.
Warmup:                          10 Minutes Typical