Distributed
By: Instrument Meter
Specialties Phones:1- 800-926-3837
1-818-841-2417 FAX: 1-818-841-2379 |
BRIGHTON |
3 ½½ DIGIT USER ADJUSTABLE SPECIFICATIONS |
INPUTS |
Power Options (User Selectable Screw Terminal) |
| DC Voltage & Current: Accuracy: ± (0.1% + 1 Count )Typical ± (0.2% + 1 Count Maximum Protection: mVDC: 200V Continous, 350V Int. VDC: 350V Continous, 500V Int. DC Shunt: 5V Maximum |
115 & 230VAC: 50 to 60 Hz & (110 & 220VDC) -15%,+ 10%, <2VA at 115VAC, <3VA at 230VAC. 12 & 24VDC Isolated: -15%,+20%, 105maDC with Backlighting 10 to 15 DC & 16 to 32VDC Non-Isolated: 105 mADC with Backlighting |
| AC TRMS Voltage & Current Accuracy: ± (0.5% + 1 Count )Typ. Res 1 Meg Protection: AC: 350V Continous, 500V Int. AC Current: Full Scale 2A & 5A; 120% Full Scale |
SCALING (AC
TRMS,Process,DC Isolated Inputs) Full Scale SPAN Adjustment: Coarse Adjustment: Four Ranges set by Dip Switch 100 to 400 Counts 800 to 1500 Counts 400 to 800 Counts 1500 to 2000 Counts Fine Adjustment: 25 Turn Potentiometer Zero OFFSET Adjustment: Fine Adjustment with 25 Turn Potentiometer. ± 15% of Full Scale (for Process Input) ± 10% of Full Scale (for AC TRMS Input) |
| Frequency: Accuracy: 40.0 to 199.9 Hz Range: ± 0.2Hz. 40 to 70 Hz ± 0.5Hz. 70 to 199.9 Hz 40 to 600 Hz Range: ± 2Hz. 40 to 600 Hz Less than 0.2 Hz error for up to 20% Third Harmonic Distortion |
|
| Loop Powered Process (4 to 20mADC): Protection: 30mA Forward, 75MADC Reverse Burden: 2.2 Max with Reverse Current Protection 1.5V Options Contact IMS Operating Temperature: -30° to +65°C |
SCALING (Loop Power, DC Shunt & Non-Isolated Full Scale SPAN Adjustment: Coarse Adjustment: Four Ranges set by Dip Switch 100 to 250 Counts 500 to 1000 Counts 400 to 500 Counts 1000 to 2000 Counts Fine Adjustment: 25 Turn Potentiometer Zero OFFSET Adjustment (Loop Powered Only) Three Choices set by Dip Switch: -20 to +20 of SPAN True Zero (4maDC=20% of SPAN). Fine Adjustment: 25 Turn Potentiometer |
| Process (4 to 20mADC): Protection: 100mADC Burden: 240mVDC @ 20mADC |
ENVIRONMENT Operating Range: - 0 to +40°C Standard -20 to +60°C Optional Storage Range: -10 to +60°C Standard -30 to +70°C Optional |
DISPLAY |
BACKLIGHT OPTIONS |
| Digits:
3½ ( ±1999) Type: 7 Segment LCD Height: 0.5" (12.7mm) Polarity: Automatic, (-) Displayed Overload: Three lower order digits blank for >1999 counts Decimal Point: 3 Position, Switch Selectable |
Non-Backlit
Red Negative Green Positive Green Negative |
PERFORMANCE |
|
| Conversion Rate:
2.5 per Secont Normal Mode Rejection: >30db @ 60Hz. Warmup: 10 Minutes Typical |
Phones: 800-926-3837....818-841-2417 FAX 818-841-2379
Jump to IMS (Instrument Meter
Specialties) Home Page)
We accept Visa - Mastercard - American
Express
Copyright © 1999 Instrument Meter Specialties