 Generators

Bearingless AC Generators Model 758

Basic These are AC generators of the most basic form, consisting of only a stator and a permanent magnet rotor wich mounts on a rotating shaft in the customer's equipment.  Designed primarily for use by OEM's, these extremely rugged and dependable generators have no bearings or brushes and therefore, require absolutely no maintenance.  Because they are impervious to oil, grease, and relatively high temperatures, they may be installed in inaccessible areas, such as gear boxes, which permits the saving of space and cost reduction.  They have extremely low torque burdens of less than one ounce-inch and are capable of speeds up to 100,000 rpm. 
Potted Models   Units are available with the stator windings encapsulated with an epoxy material for greater protection. These are designed with the letter "P" in the type number.
Mil-Spec Compliance.  Model 758, types XPF86 and GF86 are designed to meet Mil-S-901 high shock as required by specification Mil-T-16049.
Type Catalog No. Speed (RPM) Housing Number of
Stator Poles
Rotor
Style No.
Volt OutPut
@1000 RP

(Open Circuit)
Stator
Resistance
(Ohms ±20%)
Frequency @
1800 RPM
(Hz)
XF86
XPF86
758-998902
758-0077533
500-20,000 None 8 6 10 ± 1% 32 120
GF86
GPF86
758-9912002
758-0300008
500-20,000 Cast
Iron
8 6 10 ± 1% 32 120
XF44
XPF44
758-0055486
758-0067273
20,000-40,000 None 4 4 2 +3%
2 -0%
15 60
GF44
GPF44
758-0049982
758-0084866
20,000-40,000 Cast
Iron
4 4 2 +3%
2 -0%
15 60

XF86-draw.jpg (84881 bytes)

GF86-Spec.jpg (95693 bytes)

Rotor Installation The rotor of the generator unit should be mounted to the true center of the shaft with extreme care, particulary  in higher speed applications.  The relatively small inertia of the rotor makes it possible to secure it to the shaft with a right hand thread regardless of the direction of the rotation.  It is recommended that a steel screw having an SAE thread be used to permit maximum tightening.  NOTE: DO NOT press fit the rotor to the shaft, or the rotor will shatter because of the brittle nature of the magnetic rotor material.